    fuling inverter manual pdf

    Current Inspection Circuit Failure(E015) Whether it is normal after the C hange Hall device C heck if Hall device is normal main control board fault renewal of the main control board Check if the drive board is normal. The frame includes frame error det ection field calculated on the basis of This part is the defini tion of the communication data addre ss, used to control inverter operation, and CRC. S tan d a r d E x te nsio n Ca bl e: Le n g t h Mo d e l ne t w o rk c a b le c o m p an y na me 3. We have 2 Fuling Inverter DZB300 Series manuals available for free PDF download: User Manual Open-loop vector control inverter. Ge tting Started This manual will be helpful in the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drives. To guarantee safe operation of the equipment, read the fo llowing safety guideline s before connecting power to the AC drives. Keep this operating manual handy an d distribute to all users for refere nce. ! WARNINGATTENTION: Always read this manual thoroughly before using DZB series AC Motor Drives. DANGER! AC input power must be disconnected before any maintenance. WARNING! Do not c onnect or disconnect wires and connectors while power is applied tothe circuit.Maintenance must be performed by qualified technicians. The DC-link capacitor remains charged with a ha zardous voltage even after input power is removed. ATTENTION: Grounding the DZB100B drive is done by c onnecting the Earth Ground to the driveground terminal. CAUTION: There are highly sensitive components on the printed circuit boards. These components areespecially sensitive to ESD (electrostatic discharge). To avoid damage to the drive,do not touch components or the circuit boards until static control precautions have been taken. CAUTION: Never connect the main circuit output terminals U, V, and W directly to the AC main circuitpower supply as this will damage the drive.

    • fuling inverter manual pdf, fuling inverter dzb 312 manual pdf, fuling inverter dzb 300 user manual pdf, dzb series fuling inverter user manual pdf, fuling inverter manual pdf, fuling inverter manual pdf free, fuling inverter manual pdf online, fuling inverter manual pdf converter, fuling inverter manual pdf file, fuling inverter manual pdf 2017, fuling inverter manual pdf maker, fuling inverter manual pdf 2016, fuling inverter manual pdf software.

    Ge tting Started This manual will be helpful in the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drives. Special Usages The user can consult our company if he wants to use another method instead of the recommended Chapter 2 Product Introduction connecting method provided in the manual, such as shared DC bus. 12. The difference is: pressing DATA will save the parameters and return to second le vel menu and then shift to the next function c ode, while pressing PRG will return to second level menu without saving the Displayed. Able to set up frequency command, and memorize 6 Remote communication this set frequency when the inverter is power down. When the power is back,automatically combine it with The frequency command is given in the communication mode by upper position machine.For details, “. Inverter will not run if it detect operating command terminal O u tp u t F r e q u e n c y f is valid. At this mode EN is the Enable terminal, SW1 or external terminals. Output fre quency Traverse frequency function means that the inverter output frequency is traversing up and down around FDT delay the set frequency. Func tio n Default Setting Range Name Cod e Value This parameter is to determine the assignment channel of the proce ss PID target value. The bigger the P, the bigger Function Default Setting Range N ame Code Value the adjusting strength is.Once the fault occurs, Transient powe r cut exists or not motor driver inverter reset the protection function starts, the inverter stops inputting, the fault relay contact point is activated, and the. Over voltage during deceleration(E00A) Adjust the voltage within The motor protection parameter The input voltage is too high or not Correctly set up the parameter normal range F5.01 setting is suitable or not. EEPROM read-write failure(E00F) 16.

    Wiring can only be done after the mains input is cut off, otherwise there will be danger of electric shock. Please connect the inverter to the ground according to the standard, otherwise there will be danger of electric shock. Do not open the cover of the inverter after power-on, otherw ise there will be danger of electric shock. Do not touch the inverter and its circuit with wet hand, other wise there will be danger of electric shock. Do not touch the inverter terminals, otherw ise there will be danger of electric shock. At power-on, the inverter will perform the security check of the external heavy-current circuit automatically, so at this time please do not touch the terminals U, V and W, or the terminals of motor, otherwise there will be danger of electric shock. - 1- - 2- DZB Series Chapter 1 Safety and Cautions DZB Series Chapter 1 Safety and Cautions 1.2 CautionsNote 1. Check the Insulation of the Motor If parameter identification is required, please pay attention that the rotating motor may injure people, otherwise ac cident may occur. Do not change the factory settings, otherwise the inver ter may be damaged. When the motor is used for the first time, or reused after storing for a long time, or in regular checkup, the user mus t check the insulation of the motor to prevent the poor insulation of the windings of motor from damaging the inverter. The motor connection must be divided from the inverter during the insulation che ck. Please consider the capability of the mechanical devices whe n the customer needs the inverter to run at the frequency higher than 50Hz. 4. Motor He at and Noise Since the output voltage of the inverter is in PWM wave with some harmonics, the temperature may rise, the noise and vibration may increase compared with the inverter running at main frequency. 5.

    CAUTION: Do not apply the antirust to screws for fastening drives; Please cle an the drives and screwswith dry c loth or alcohol, not with synthetic cleaner. Fasten the screws with washers and rated torque lest the enclosure corners of drive s be distorted. Operations which are not performed according to requirements may cause moderate hurt or light hurt or equipment damage. Danger Do not connect the input terminals with the output termina ls (U, V, W), otherw ise the inverter may be damaged. Ens ure the wiring mee t the EMC requirements and the local safety standard. The wire size shall be det ermined according to the manual, otherwise accident may occur. Pleas e confirm the mains voltage level is c onsistent with that of the inverter and the input and output wirings are correct, and check if there is any short circuit in peripheral circuit and if the wiring is fixed and fast, otherwise the inverter may be damaged. Mount the cover plate properly before power-on the inverter, otherwise there will be danger of electric shock. 2.During InstallationDanger Note Mount the inverter on incombustible surface like metal, and keep awa y from flammable substances. Otherwise it may cause fire. Note Dielectric strength test had been done at factory. Therefore, user needs not do this test again, otherwise accident may occur. All the peripheral parts shall be connected correctly according to the manual, or accident may occur. When more than two inverters are to be installed in one cabinet, ple ase pay attention to the installation locations to ensure the cooling effect (refer to Chapter 3 Mechanical and Ele ctrical Installation). Do not drop the lead wire stub or screw in the inverter, or the inverter may be damaged. 5.After Power-on Danger 3.WiringDanger Only the qualified electrical engineer can perform the wiring, otherwise there will be danger of electric shock. A circuit breaker must be installe d between the mains and the inverter, otherwise there w ill be danger of fire.

    Running Danger Do not approach the equipment when restart function is enabled, otherwise there w ill be danger of injury. Do not touch the fan and the discharging resistor to check the temperature, otherwise burning may occur. Non-prof essional person shall not measure the sign Recommended VM1000 Series General Inverter User Manual INVERTER will be damaged and the guarantee is voided. Discover everything Scribd has to offer, including books and audiobooks from major publishers. Start Free Trial Cancel anytime. Report this Document Download Now Save Save Fuling Inverter User Manual For Later 100% (5) 100% found this document useful (5 votes) 14K views 54 pages Fuling Inverter User Manual Uploaded by Fayzan Hannan Description: Full description Save Save Fuling Inverter User Manual For Later 100% 100% found this document useful, Mark this document as useful 0% 0% found this document not useful, Mark this document as not useful Embed Share Print Download Now Jump to Page You are on page 1 of 54 Search inside document Browse Books Site Directory Site Language: English Change Language English Change Language. Page 5 DZB Series DZB Series Chapter 1 Safety and Cautions Chapter 1 Fuling inverter DZB300 Series Pdf User Manuals. View online or download Fuling inverter DZB300 Series User Manual. 26 Jun 2014. Thank you! Fuling Inverter DZB300 Series User Manual (54 pages) dzb300 series High-performance general-purpose inverter, open-loop vector control inverter. 26 Jun 2014 please refer to this operation manual before using. This inverter uses advanced IGBT silent design combining with vast technology over the years to complete DZB200 Series Inverter pdf manual download. Related Manuals for Fuling Inverter DZB200 Series. Hello, I need the Manuel for DZB312B003?.7L2DK. To start viewing messages,I found an english manual online, but I can't seem to get it into the programming mode so I can change over to terminal control. But it won't do anything.

    Pressure-sensitive Device or Capacitor at the Output Side of the Inverter Because the inverter outputs PWM wave, the capacitor used for improving power factor and pressuresensitive res istor used for lightening-proof shouldn't be installed at the output side of the inverter, otherwise the inverter may have transient over-current and may be damaged. 6. Switches Used at the Input a nd Output terminal of the Inverter If the contactor is required to be installed betw een the inverter and the power supply, it is prohibited to start or stop the inverter with the contactor. If the user has to use the contactor to start a nd stop the inverte r, the interval between the start and stop shall be less than one hour. Frequent charging and discharging ma y reduce the life of the capacitor. If the switches like contactors are connected between the output terminal and the motor, make sure to start and stop the inverter when the inverter has no output, otherwise the modules in the inverter may be damaged. 7. Usage Outside the Range of Rated Voltage The DZB series inverter shall not be used out of the specified range of operation voltage, otherwise the internal components of the inverter may be damaged. If needed, please use corresponding voltage regulation device to change the voltage. 8. 3-phase Input Modified Into 2-phase Input The modification of DZB series inverter from 3-phase input to 2-phase input is not allowed, or fault may occur. 9. Lightning Strike Protection There are lightning protection devices inside the inverter, But the user should install other lightning protection device at the front end of the inverter if lightning strike occurs frequently. 10. Altitude and Deration When the altitude is higher than 1000m, the cooling effect of inverter is deteriorated because of the rarefaction of air, the deration must be used and please consult our company for detailed technical support. 6.

    Cheers - Matt The site is 100% free to join and use, so join today! Hopefully you can make sense of it. Only info I have are photos attached. Hopefully you can make sense of it. I'll fix and re-send. I'll fix and re-send. Refer to page 8 of the PDF file. Refer to page 8 of the PDF file. Showing recent items. Manual and User Guide for many equipments like mobile phones, photo cameras, motherboard, monitors, software, tv, dvd, and others. I found manuals that contain only. Attention: ? Al ways read this manual thoroughl y before using DZB series A C Motor Drives. ? Do not connec tSep 11, 2018 - the following safety guidelines before connecting power to the AC drives. DZB200 inverter provides password protection for users. Fuling inverter DZB200 Series Pdf User Manuals. View online or download Fuling inverter DZB200 Series User Manual. View and Download Fuling Inverter DZB200 Series user manual online.Excitation Mar 19, 2010 -. Cutting at 3mm doc with above settings the inverter pulls about 1.5A. Off the top of my head Gwizard calc estimated the required power to be approx 250w which I assumed it should be more than capable of at that rpm. My question is would a good quality (branded) vfd capable of open loop solve my problems? The spindle stayed quite cool to touch after 5 hours of cutting maybe 30 degrees on the outside jacket. Any help would be great thanks Also had a reserved function which needed to be set to 1235. These manuals are a little bit cryptic Spindle cuts really nicely now.Also had a reserved function which needed to be set to 1235. These manuals are a little bit cryptic Spindle cuts really nicely now. I still feel it is somewhat under powered as kept increasing the width of cut until it would start to stall at 240w (assuming gwizard is correct ofc) see attached picture.I still feel it is somewhat under powered as kept increasing the width of cut until it would start to stall at 240w (assuming gwizard is correct ofc) see attached picture.

    Mactec54 knows VFD settings so listen to what he is asking.Also noticed it has DZB 215DK sticker on the inside, would that indicate a 200 series and maybe not a 300?Also noticed it has DZB 215DK sticker on the inside, would that indicate a 200 series and maybe not a 300? I think I will just buy a new vfd anyway any brands you could recommend?I think I will just buy a new vfd anyway any brands you could recommend? For further information on cookies, please refer to our privacy policy. More infomations about the cookies and further configurations Agree. I'm using a mix of Hitachi, Siemens, Omron and ABB drives in my workshop, they are more expensive than the Chinese equivalents but the manuals are written in english, which for me makes them worth the extra as my Chinglish isn't very good;-) Regards, Nick. Download 63542313 DZB100 Series User Manual.Getting Started This manual will be helpful in the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drives. To To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC drives. Keep this operating manual handy and distribute to all users for reference. ! WARNING AT T E N T I O N: Al Alwa ways ys re read ad th this is man manual ual tho thoro roug ughly hly bef befor oree us usin ing g D Z B 1 0 0 se seri ries es AC Mo Moto torr Dr Drive ives. s. DANGER! AC input power must be disconnected before any maintenance. WARNING! Do not connect or disconnect wires and connectors while power is applied to the circuit. Maintenance must be performed by qualified technicians. The DC-link capacitor remains charged with a hazardous voltage even after input power is removed. AT T E N T I O N: Grounding the DZB100B drive is done by c o n n e c t i n g t h e E a r t h G r o u n d t o t h e drive ground terminal. These components a r e e s p e c i a l l y s e n s i t i v e t o E S D ( e l e c t r o s t a t i c d i s c h a rg e ).

    I can't scroll through the sub menus. The manual mentions a password but the unit never asks for a password (not that I've set one up). It should hopefully be factory default settings but I can't find anything about to reset it anyway. Does anyone have any ideas with the beast.Oh well I'll just keep doing it all manual for now. I've tried emailing Fuling but their emails just bounce back again. Cheers anyway Matt But for now this is just a project. Please tell me if you are solving this issue and if your connection with Mach3 is working. I hope I'll be able to support this thread but this will happen just after I'll finish my router and have anything in place and working. Best regards, Seb I was able to get it into terminal mode. I still have some different firmware I guess though because the table was slightly different. But I was only after terminal mode which worked ok for me. The default contacts allow me to remotely select the run forward command which is all I'm after. Hope you have fun! Let me know how you go with RS485. Cheers Matt I cannot test it yet in Communication mode because the RS485 adapter doesn't arrive. In the mean time I've read the manual and some topics about the Huanyang inverter ( Huanyang VFD controller plugin ) and I suppose following: The Fuling inverter should be set up just like the Huanyang inverter, with the same Mach3 plugin, we just have to find the correct settings for it. The inverter have to work in Communication mode (through RS485), not Terminal mode, I think. I repeat, I doesn't test it yet, I'll do it right after I'll have the RS485 adapter. Until then, I'm wondering about one setting: F0.01 If F0.01 will be 2 (Communication) instead 0 (Keyboard, default), I will lose the keyboard control over the VFD. How can I will return to the Keyboard mode. I'm a little bit scared about this parameter. Best Regards The ModIO plugin for Mach3 is reading the VFD's parameters without problems.

    For now, I have to find out how to control the spindle through Mach3 because with the default settings don't work. For now, I have the VFD successfully connected through the RS485 line and Mach3's Modbus can read any serial address from VFD. Could somebody give me some advices? Thanks. I cannot figure why the JOG command doesn't work. Communication setting address (page 95) is used for setting the running frequency (speed). If somebody is interested, please ask. Regards, Seb I've just decided I need to control speed myself, and maybe it's worth investing in a RS-485 adaptor to achieve this. It seems like MODBUS should be easy enough (well after hearing from you anyway). Matt Cheers - Matt Which RS-485 adaptor are you using? Thank you So, the brains I've made are attached. Vfdrun.brn is used for sending commands like RUN and STOP Vfdspeed.brn is used for sending speed's parameters. I also attach the modbus settings. I think that's all. For any issues, please ask. Any hints and suggestions are welcome. Regards, Seb Looking at the values in the P registers (my VFD has P00 to P157) I found that a manual for a DZB100 was the closest match. e.g parameter 0-5 match and parameters 7 to 23 on the vfd match 6 to 22 in the manual. Switching p76 to 0 allowed me to adjust other settings. The router I have is controlled from NCstudio and it looks like it was wired so it can only set 2 speeds (rather than 7) and was maxing out the freq at 150 which only gives 9000rpm (measured with a laser tachometer). Tweaking P18 allows me to get set a higher speed. Now that I know how to tweak the VFD it means I can switch the router over to mach3 otherwise plan B would have been to swap the VFD for something which does have a useful manual. I never get too far with mine and usually end up doing something else instead. I might one day look for the other manual like you said. The problem is finding the time to do it when the benefits aren't that important to me.

    To avoid damage to the drive, do not touch components or the circuit boards until static control precautions have been taken. CAUTION: Ne ve r c on ne ct th e ma in ci rc ui t ou tp ut te rm in al s U, V, an d W di re ct ly to th e AC ma in c i r c u i t p o w e r s u p p l y a s this will damage the drive. CAUTION: Do not apply the antirust to screws for fasten ing drives; Please clean the drives and screws with dry cloth or alcohol, not with synthet ic cleaner. Fasten the screws with washers and rated torque lest the enclosure corners of drives be distorted. This manual is for DZB100 Series AC Motor Drive. -1 - DZB100 DZB1 00 Seri Series es In tr od uc ti on Chapter 1 Introduction T he he p ur ur po po se se o f t hi hi s c ha ha pt pt er er i s t o p ro ro vi vi de de s pe pe ci ci fi fi c, c, y et et s im im pl pl e i nf nf or or ma ma ti ti on on t o unpack, install t he he AC drive. This chapter contains information on the following: 1.1 Receiving, Transportation, and Storage 1.2 Nameplate Information 1.1 Receiving, Storage and Transportation The AC motor drive has gone through rigorous quality control tests at the factory before shipment. After receiving the AC drive, check for the following. Receiving 1.Check to make sure that the package includes an AC drive,the User Manual,dust covers and rubber bushings. 2.Inspect the unit to insure it was not damaged during shipment. 3.Make sure that the part number indicated on the nameplate corresponds with the part number of your o rder. Storage The AC Drive should be kept in the shipping carton before installation. In order to retain the warranty coverage, the AC drive should be stored properly when it is not to be used for an extended period of time. Make sure that the AC drive is wired according to the instructions contained in this chapter. The instructions should be read and understood before the actual installation begins. 2.1 Installation Requirements 2.2 Wiring 2.3 Basic Wiring Diagram 2.

    1 Installation Requirements Install the AC drive vertically to provide proper ventilation. Adequate space isrequired between the drive and a wall or other equipment. The figure below shows the minimum space needed. All enclosures must provide adequate ventilation and the internal ambient temperature must be kept at 40 or below. Make the length of these ground leads as short as possible. 4.Should several AC drive units be installed side by side, all the units should be grounded directly to the ground poles. Do not form a loo p with the ground leads. 5.Make sure that the power source supplies the correct voltage and is capable of supplying the required current to the A C drive. Refer to specification for Rated AC Input Power.Motor Voltage should mat ch the line voltage. 6.For single phase applications, the AC input line can be connected to any two of the three input terminals R, S, T. A single phase DZB100B drive can be powered from three phase as well as single phase. Caution: Do not monitor the signals at any point on the circuit board while the AC drive is in operation. Caution: Do not connect the AC input to any of the U, V, W terminals, as this will damage the AC drive. -8 - DZB100 Series In st al la ti on an d Wi ri ng Control Circuit Wiring (1) Control terminal block designations The control leads must be routed separately from the power supply and motor leads. They must not be fed through the same cable conduit. It is recommended to run signal wiring in a separate steel conduit. The shield wire should only be connected at the drive. -9 - DZB100 Series In st al la ti on an d Wi ri ng 2.3 Basic Wiring Diagram Users must connect wires according to the fo llowing circuit diagram shown below. Do not plug a Modem or telephone line to the RS-485 communication port, permanent damage may result. Refer to F1-38 on page 44. Refer to F1-45, 46 on page 48 a nd F1-63, 64, 66 on pages 55 and 56. Refer to F1-43 on page 47. Refer to F1-00 on page 28, F1-48, 49, 50 on page 49.

    Refer to F1-42, 44 on pages 46 an d 47. Refer to F1-57 on page 53. Refer to F1-45, 46 on page 48. Refer to F1-00, 01 on page 28, F1-77, 78 on page 60 and 61. -12- DZB100 Series Di gi ta l K ey pa d O pe ra ti on Chapter 3 Digital Keypad Operation Chapter 3 describes the various controls and indicators found on the digital keypad of the DZB100 AC drive. The display panel allows the user to program the AC drive, as well as view the different operating parameters. The keypad is the user interface to the AC motor drive. Refer to the following figure for a description of the different parts. RUN STOP JOG FWD REV LED indication LED display Red lamp lights during RUN, STOP, JOG, FWD, or Indicates frequency, motor current REV operation. Jog key While pressing this key, jog speed is available. Digital Operator Run key Stop key Starts inverter drive operation. Switch to the PRGM mode to select a parameter or change the setting of a parameter. If the AC drive has stopped due to a fault, press this button to reset the drive. While the driv e is in the Program Mode, press this key once to display the current parameters. After changing the parameters, press this key again to store the new parameters. Pressing this key will cause the motor t o ramp down to 0 Hz and then ramp up to the preset speed in the opposite direction. RUN Ru n Used to start the AC drive operation. This key has no effect when the drive is set t o terminal run. Stop Used to stop the AC drive operation. These keys may also be used to scroll through different operating values or pa ra me te rs. Press and hold down either of these keys to rapidly run through the possible settings. -14- DZB100 Series Di gi ta l K ey pa d O pe ra ti on 3.2 Explanation of Screen Display Explanation of Displayed Messages Displayed Message Description Displays the AC drive output frequency controlled by the Maximum Output Frequency (F1- 03), Jog Frequenc y (F1- 16), or by the Multi-Function Input Terminals (F1-39-41).

    If the frequency source originates from the Digital keypad, the user can use either the or key to set the frequency. Displays the output frequency present at terminals U, V, and W. Displays the input voltage. Note: Refer to Chapter 5, F1-45, 46, 63 - 66 for a detailed description of the above. Displays the output c urrent present at terminals U, V, and W Displays the specified parameter numb er. The actual parameter valu e FUNC m ay b e d is pl ay ed b y p re ss in g t he DATA k ey. Displays actual value stored within the specified parameter. FUNC Press the DATA key to store the value of the specified parameter. The display will read Fd (as shown) for approximately 1 second if the input has been accepted. After a parameter value has been set,the new value is auto matically stored in memory. To modify an entry, use FUNC or key.Then press the DATA key. -15- DZB100 Series Di gi ta l K ey pa d O pe ra ti on Explanation of the LED Indicators RUN STOP JOG FWD REV Red lamp lights during REV operation. Red lamp lights during FWD operation. Red lamp lights during JOG. Red lamp lights by pressing STOP. Red lamp lights by pressing RUN. Use the STOP key to halt operation. Refer to the Basic Wiring Diagram in Chapter 2 for information on the wiring connection. To change the o perating frequency, proceed as follows: The operating frequency may be changed in either the STOP MODE MODE Increase the frequency Decrease the frequency NOTES: Display changes every time or key is pressed. -17- or RUN mode. DZB100 Series Di gi ta l K eyp ad Op er at io n Setting parameters: Indication after power on. Press FUNC DATA FUNC DATA Press Press PRGM RESET PRGM RESET key Output current Press PRGM RESET PRGM RESET key Press return to the normal operation mode. (Data entered will not be stored.) Press PRGM RESET key key key to set the parameter setting number. Press Press key key Output frequency Frequency command Press key FUNC DATA Press FUNC DATA key to display parameter data.

    Press Press -18- FUNC DATA key to store the data. DZB100 Series St ar t U p Chapter 4 Start Up This chapter describes the steps needed to start the AC drive and typical adjustment and verification pr oc ed ur es to en su re a s im pl e a nd effi ci en t s ta rt -u p. Th e fo ll ow in g st ar t- up pr oc ed ur es de sc ri be th e most common parameter settings and system configurations. 4.1 Initial Operation - Motor Disconnected Verify that the AC power line, at the disconnect device, is within the rated power of the AC drive. Connect the AC drive to the power line. Proceed as follows to select a mode of operation. 1. Operating frequency determined by the digital keypad. Verify your operation mode works correctly, then proceed to the next section for motor connection and initial operation. 4.2 Initial Operation - Setting Parameters and connecting the Motor. Verify Minimum and Maximum Output Freque ncy Settings (F1- 08 and 03) arec orrect for your application. Verify the Motor Stop Method (F1-02) is corre ct for your application. Connect the motor to the terminals U, V, and W Check for correct motor shaft rotation (counter clockwise when viewed from the shaft). Verify the Stop command is functi oning by pressing the Stop Key on th e Digital Keypad or using your Control Terminal Stop method. This completes the basic start-up. Depending on the application, some parameter values may need to be modified.Momentary power failure operation mode selection 32 0001 Operation continues after momentary pow er lo ss. S pee d s ear ch st arts wit h the frequency reference value. 0000 0002 Operation continues after momentary pow er lo ss. S pee d s ear ch st arts wit h the minimum output frequency. Momentary power loss protection 33 Maximum allowable pow er lo ss ti me 0.3 5.0sec 2.0 34 Minimum base block time 0.3 5.0sec 0.5 35 Speed search current limit 30 -23- 20 0% 150% DZ B100 Seri es NO. Parameter Name 36 Reference freq.